Wired Alarm Panels
Hercules 10 Zone LCD Alarm Panel
LY52-110-38
- 10 Fully Programmable Zones
- Remote LCD or LED Keypad
- 4 Access Level Codes
- 2 Part Guard Arming Options
- LCD Keypad With 250 Event Memory LED Keypad With 16 Event Memory
- Non-Volatile Memory
- Programmable Timer For Entry/Exit & Bell Cut-Off
- Battery Capacitor Up To 12V 2.2Ah
- Simple To Install & Easy To Program
- Up To 4 Remote Keypads
General Specifications
| Zones | 10 programmable zones, negative loop |
| Arming/Disarming | Through remote LED Keypad, Through remote LCD Keypad |
| Alarm Memory | LED keypad 16 events, LCD keypad 250 events |
| Walk Test | Visual & audible on all zones |
| On Board Display | Light emitting diodes (LED) |
| Protection Class | Class I |
Programme Timers
| Full guard entry/exit delay 1 second - 15 minutes |
| Part guard exit delay 1 second - 15 minutes |
| Siren duration 3, 5 or 15 minutes |
Programmable Functions
| Full guard & 2 x part guard |
| 10 fully programmable zones |
| Timed entry/exit, walk through, instant personal alarm, tamper, fire, secure final set, double knock, disable/Isolate |
| Codes 4 user, 1 engineer |
| Quick set facility |
| Engineer reset |
| Push button final set |
| Installer message displayed on LCD keypad |
| Zone location names on LCD keypad |
| Time & date displayed on LCD keypad |
European Standards
| Conforms to European law (EU) Low Voltage Directives LVD 73/23/EEC (amended 93/68/EEC) and Electro-magnetic Compatibility (EMC) 89/336/EEC (Amended by 92/31/EEC and 93/68EEC) RoHS |
Power Supply
| Primary mains supply voltage rating | 230Vac |
| Maximum current rating | 1000mA |
| Rechargeable backup battery | 12Vdc |
Environmental Specifications
| Operating Temperature | -0ºC - + 40ºC |
| Storage temperature | -20ºC - + 60ºC |
| Maximum humidity | 95% non-condensing |
| EMC environment | Residential/Commercial |
Physical Specifications
| Dimensions | 253mm X 195mm X 61mm |
| Housing material | ABS |
LCD Remote Keypad
| Display | 16 X 2 backlit LCD |
| Operating Voltage | 12Vdc |
| Standby | 60mA |
| In alarm | 100mA |
LED Remote Keypad
| Operating Voltage | 12Vdc |
| Standby | 40mA |
| In alarm | 70mA |
Electrical Specifications
| Quiescent current | 50mA |
| Alarm Current | 100mA |
| Set + output | When low: 1.0Vdc, when high 12Vdc |
| Switched positive voltage | When low: 1.0Vdc, When high 12Vdc |
| Bell voltage output | 12Vdc |
| External speaker voltage output | 12Vdc 16ohm, max Current: 220mA |
| Strobe voltage output | 12Vdc latching |
| Positive loop threshold (zones1-7/tamper) | Minimum open resistance: 70K, Maximum closed resistance: 10K |
| Negative loop threshold | Zones 1-10 |